plugyard
A terminal tool that simulates EV chargers, so you can develop and test a CSMS (charging station management system) without hardware. Its command line follows Docker's conventions: a file describes a kind of charger, a YAML file starts many of them together, and ps and exec operate on the running ones.
Beta. plugyard does everything its V1 specification lists, and is tested against a fake CSMS and an independent OCPP library. It has not yet been used with many real CSMS products, so file formats and JSON output may still change before 1.0. Please report what does not work with yours.
Install
Windows, in PowerShell:
irm https://raw.githubusercontent.com/Amraa1/plugyard/main/install.ps1 | iex
Linux and macOS:
curl -fsSL https://raw.githubusercontent.com/Amraa1/plugyard/main/install.sh | sh
Either one downloads the latest release for your system, checks it against the release's checksums, and puts plugyard in your user folder: %LOCALAPPDATA%\Programs\plugyard on Windows (added to your PATH), ~/.local/bin elsewhere. No administrator rights are needed. Open a new terminal afterwards and run plugyard version, which prints the version you have.
Other ways:
- With Go 1.26 or newer:
go install github.com/Amraa1/plugyard@latest
- By hand: download the archive for your system from the releases page, unpack it, and put
plugyard somewhere on your PATH. Builds exist for Windows, Linux and macOS, each for x86-64 and ARM64.
The programs are not code-signed. If you download one by hand, Windows SmartScreen may say it is unrecognized (choose "More info", then "Run anyway"), and macOS may refuse to open it until you run xattr -d com.apple.quarantine ./plugyard. The install scripts and go install do not trigger these warnings.
Update
plugyard update --check # is there a newer release?
plugyard update # install it
plugyard update replaces the program with the latest release, after checking the download against its checksums. Your saved chargers and logs are kept. Stop running sites first (plugyard site stop): a site started by one version cannot be controlled by another. If you installed with go install, run that command again instead.
Uninstall
plugyard uninstall
It shows what it is about to remove, with the full paths, and asks first:
- the program, and its folder when that folder is plugyard's own;
- on Windows, the entry the install script added to your PATH;
- your saved chargers and logs.
--keep-data leaves these, for when you plan to install again.
Stop running sites first, as for an update. --yes skips the question, for scripts. Files that plugyard init wrote in your own folders are yours and stay.
Quick start
You need a CSMS that accepts OCPP 1.6J over WebSocket. The examples assume it listens at ws://localhost:9000/ocpp.
plugyard init my-site --csms ws://localhost:9000/ocpp # writes site.yaml, Chargerfile and scenario.yaml
cd my-site
plugyard site up # three chargers connect; Ctrl+C stops them
In a second terminal:
plugyard ps # the three chargers and their connectors
plugyard scenario run scenario.yaml # plugs in, charges, faults one charger and unplugs, by script
plugyard logs CP-1 # every OCPP message CP-1 exchanged with your CSMS
That is a working setup. The rest of this page explains the files init wrote and what else you can do.
The files, step by step: twenty chargers
1. Describe a kind of charger in a file called Chargerfile:
vendor: Acme
model: FastOne 50
firmware: 1.4.2
connectors:
- { id: 1, type: CCS2, maxPower: 50kW }
2. Describe the site in site.yaml, next to it:
name: demo
csms:
url: ws://localhost:9000/ocpp
chargers:
fast:
model: ./Chargerfile
count: 20
id: "FAST-{n}"
count: 20 makes twenty chargers, and {n} in id is each one's number, so they are called FAST-1 to FAST-20. Each connects to the CSMS URL with its own ID appended, such as ws://localhost:9000/ocpp/FAST-1.
3. Check it, then start it:
plugyard site validate # lists the chargers the file would create
plugyard site up # starts them and shows their logs; Ctrl+C shuts them down
That is all. In a second terminal:
plugyard ps # every charger, its name, connection and connector statuses
plugyard exec FAST-1 plug # plug an EV into FAST-1
plugyard exec FAST-1 tap 04A1B2C3 # present a tag: Authorize, then StartTransaction
plugyard exec 'FAST-*' plug # act on every charger whose ID matches
plugyard exec FAST-1 unplug # ends the transaction with StopTransaction
A ready-made version of this site, with more settings shown, is in examples/site.yaml.
Running in the background
plugyard site up -d # returns once the site is running
plugyard site ls # the sites that are running
plugyard site stop # shuts the site down
plugyard site start # brings it back as it was
The site keeps running after you close the terminal, and ends when you sign out.
See what is happening
plugyard logs FAST-1 -f # events and every OCPP message, as they happen
plugyard logs 'FAST-*' --events --since 10m
plugyard site logs -f # the whole site
plugyard stats # live power, energy and message counts
plugyard inspect FAST-1 # everything about one charger
plugyard info # every site on this machine, where data is kept, and which build this is
- Logs are kept on disk, so they are there for a site in the background and after a stop. A log holds the newest 30 MB;
log: { maxSize: 100MB, files: 5 } in the site file changes that.
inspect shows the configuration keys with their current values, the charging profiles your CSMS installed, the EV and transaction on each connector, and the messages still queued for the CSMS.
stats refreshes every second in a terminal. --no-stream prints once.
- Prefer
docker container ls to docker ps? Every charger command is also in the charger suite: plugyard charger ls is plugyard ps, plugyard charger logs is plugyard logs, and so on.
In scripts and CI
Every listing command takes --format json and prints one object per line. Exit codes are 0 for success, 1 when something could not be done, and 2 for a mistake in the command or a file.
# Wait until FAST-1 is charging, in place of a guessed sleep; exit code 1 if it is not within 30 seconds
plugyard exec FAST-1 tap 04A1B2C3
plugyard wait FAST-1 Charging
# The same for several chargers, a connection state, and a longer time
plugyard wait 'FAST-*' online --timeout 2m
# Did FAST-1 send a StopTransaction?
plugyard logs FAST-1 --format json | jq -e 'select(.kind == "sent" and .message[2] == "StopTransaction")'
# Total power of the site, in watts
plugyard stats --format json | jq -s 'map(.powerW) | add'
# The value of one configuration key
plugyard inspect FAST-1 --format json | jq -r '.configuration[] | select(.key == "HeartbeatInterval").value'
Run a scenario
A scenario is a file of timed actions, for tests that run by themselves:
name: commute
steps:
- { at: 0s, charger: "FAST-*", do: plug, ev: longrange }
- { at: 5s, charger: "FAST-*", do: tap, tag: 04A1B2C3 }
- { at: 10m, charger: FAST-3, do: fault, code: GroundFailure }
- { at: 20m, charger: FAST-5, do: kill } # a power cut mid-charge
- { at: 21m, charger: FAST-5, do: start }
- { at: 30m, charger: "FAST-*", do: unplug }
plugyard scenario validate commute.yaml # check it, and see which chargers each step would act on
plugyard scenario run commute.yaml # run it against the running site
plugyard scenario run commute.yaml --step 3 # try one step now, while you are writing it
- A step does what
exec does, with the same options, or powers chargers with stop, start, restart and kill.
- Times follow the site's speed. Against
plugyard site up --speed 60, these thirty minutes take thirty seconds, and the EVs have charged for thirty minutes.
- It fits CI. The exit code is
0 when everything succeeded, 1 when an action failed, and 2 when the file has a mistake. --fail-fast stops at the first failure, and --format json prints one object per action.
A longer one, with a network drop and a power cut, is in examples/scenario.yaml.
Editor support
The files plugyard init writes start with a line that names their JSON schema, so an editor with YAML support (VS Code with the YAML extension, JetBrains IDEs) completes settings and marks mistakes as you type. For your own files, copy that first line, or print a schema with plugyard schema site, plugyard schema chargerfile or plugyard schema scenario.
Chargers remember
A charger keeps its state when it is stopped: its meter, its configuration, the EV plugged into it, and anything it still owes the CSMS. So your CSMS meets the same chargers every time, with meters that never run backwards.
plugyard stop FAST-1 # orderly shutdown: StopTransaction, then the connection closes
plugyard start FAST-1 # the same charger boots again
plugyard kill FAST-1 # power cut: the connection drops with no message
plugyard start FAST-1 # it boots and reports the transaction with reason PowerLoss
plugyard ps -a # also lists the stopped chargers
plugyard rm FAST-1 # wipes the charger's saved state
kill is how you test what your CSMS does when a charger loses power mid-transaction. The same happens if the machine crashes or plugyard is ended from the task manager: the next start reports PowerLoss with the last meter reading saved, which is at most five seconds old.
| To |
Use |
| Stop a site and come back to it later |
plugyard site stop, then plugyard site start |
| Apply changes made to the site file |
plugyard site up |
| Take a site off the list but keep its state |
plugyard site down |
| Start over with fresh chargers |
plugyard site down --reset |
If you edit a site file so that saved state would be lost, for example by removing a charger, site up lists what is affected and asks first. --yes answers in advance, for scripts.
Test what goes wrong
Real chargers fail, and a CSMS has to cope. plugyard lets you cause the failures you would otherwise wait months to see in the field, one command each.
A hardware fault. The connector reports Faulted with the error code, and a transaction running there ends:
plugyard exec FAST-1 fault GroundFailure
plugyard exec FAST-1 fault OverCurrentFailure --info "phase L2" --vendor-code E-42
plugyard exec FAST-1 clear # the fault is gone
plugyard exec FAST-1 fault InternalError -n 0 # the whole charger, not one connector
The codes are the fifteen of OCPP 1.6: ConnectorLockFailure, EVCommunicationError, GroundFailure, HighTemperature, InternalError, LocalListConflict, OtherError, OverCurrentFailure, OverVoltage, PowerMeterFailure, PowerSwitchFailure, ReaderFailure, ResetFailure, UnderVoltage and WeakSignal. plugyard exec --help lists them too.
A lost connection. The charger keeps charging, queues what it has to say, and sends it in order when it is back:
plugyard exec FAST-1 offline # stays away until...
plugyard exec FAST-1 online
plugyard exec 'FAST-*' offline --for 30s # twenty chargers drop out and return
A reboot, or a power cut:
plugyard exec FAST-1 reboot # ends the transaction, boots again
plugyard kill FAST-1 # no goodbye; PowerLoss on the next start
| What happens in the field |
How to cause it |
What your CSMS sees |
| A connector faults mid-charge |
exec ... fault <code> |
StopTransaction (reason Other), then StatusNotification Faulted with the code |
| The charger's network drops |
exec ... offline |
Silence, then BootNotification and the queued messages in order |
| Your CSMS restarts |
Restart your CSMS |
The charger retries by itself, boots and replays |
| Your CSMS answers a message with an error |
Return a CallError |
The same message again, up to three times |
| The charger reboots |
exec ... reboot, or send Reset |
StopTransaction (reason Reboot, SoftReset or HardReset), then BootNotification |
| The charger loses power |
plugyard kill |
The connection drops; StopTransaction (reason PowerLoss) after the next start |
Your CSMS is in charge
The charger answers the requests a CSMS sends, with no action from you: RemoteStartTransaction, RemoteStopTransaction, Reset, GetConfiguration, ChangeConfiguration, ChangeAvailability, UnlockConnector, ClearCache, DataTransfer, TriggerMessage, and the smart charging and firmware requests below. A configuration key your CSMS changes is saved, and stays changed across restarts. What each request does is in docs/SPEC.md, section 8.
Smart charging
Send your CSMS's charging profiles and watch the charger obey them:
| Your CSMS sends |
The charger |
SetChargingProfile with a 16 A limit |
Delivers 11.04 kW from then on (16 A x 230 V x 3 phases) |
| A limit of 0 |
Reports SuspendedEVSE, keeps the transaction open, and returns to Charging when the limit rises |
ClearChargingProfile |
Goes back to full power |
GetCompositeSchedule |
Answers with the limit that results from every installed profile |
- All three purposes (
TxProfile, TxDefaultProfile, ChargePointMaxProfile), stack levels, and Absolute, Relative and Recurring schedules work as OCPP 1.6 describes.
- Limits in W or in A are both accepted. For amps, tell the Chargerfile what the supply is if it is not 3 phases of 230 V:
phases: 1 for a single-phase wallbox.
- To see the limit from your CSMS, add
Power.Offered or Current.Offered to the MeterValuesSampledData key. The charger's log also says when a limit changes.
- Schedules follow the real clock even with
--speed, so for a quick test send periods a few seconds long.
Profiles are saved with the charger. The rules are in docs/SPEC.md, section 8.
Firmware updates and diagnostics
Press "update firmware" in your CSMS and watch the charger go through it. No firmware file is needed: the charger fetches nothing, it reports what a real charger reports. Diagnostics are real: the charger uploads its own log to the place your CSMS names.
| Your CSMS sends |
The charger |
UpdateFirmware for ftp://host/fw-2.4.1.bin |
Reports Downloading, Downloaded, Installing and Installed, then reboots and sends BootNotification with firmware fw-2.4.1 |
UpdateFirmware during a transaction |
Downloads, then waits for the transaction to end before it installs |
GetDiagnostics for ftp://user:password@host/dir/ |
Answers with a file name, reports Uploading, uploads its log there under that name, and reports Uploaded, or UploadFailed if the server cannot be reached or refuses |
To test the unhappy path, tell the charger what goes wrong next:
plugyard exec FAST-1 fail download # the next update ends with DownloadFailed
plugyard exec FAST-1 fail install # ... or with InstallationFailed
plugyard exec FAST-1 fail upload # the next diagnostics upload ends with UploadFailed
-
Each step of a firmware update takes 10 seconds, or less with --speed.
-
The diagnostics file holds what plugyard logs FAST-1 shows, and startTime and stopTime choose the lines. It is sent the way the location says:
| Location |
Sent with |
ftp://, ftps:// |
FTP, or FTP with encryption |
sftp:// |
SFTP, over SSH |
http://, https:// |
An HTTP PUT |
For an ftps:// or https:// server with a self-signed certificate, add insecureSkipVerify: true under uploads in the site file.
-
A charger uploads only to the machine its CSMS is on, unless you allow more. Your CSMS chooses the address, so this keeps a CSMS that has been broken into from pointing the upload at your internal network. A CSMS and a file server on your own machine work with no setting. For a file server elsewhere, name it in the site file:
uploads: { allow: [files.example.com] }
With plugyard run, use --allow-upload files.example.com. A refused upload ends in UploadFailed, and the charger's log shows the line to add.
The details are in docs/SPEC.md, section 8.
Names
Every charger also gets a name, as Docker containers do: brisk_volt, quiet_ampere. A name is unique on your machine, so it always means one charger, even when two sites use the same charge point ID. Use it wherever a command takes a charger:
plugyard exec brisk_volt plug
Give a charger a name of your own with name: in the site file (on an entry that creates one charger) or --name on plugyard run. Your CSMS never sees the name, only the charge point ID.
When you need more from the IDs
| In the site file |
Charge point IDs |
id: "FAST-{n}", count: 3 |
FAST-1, FAST-2, FAST-3 |
id: "FAST-{n:03}", count: 3 |
FAST-001, FAST-002, FAST-003 |
id: "{n:012}", count: 2, start: 202310090165 |
202310090165, 202310090166 |
ids: [12994897, p025b2036387] |
exactly those two |
Other things a site file can do
- Keep secrets out of the file.
password: ${CSMS_PASSWORD} reads an environment variable, and ${CSMS_URL:-ws://localhost:9000/ocpp} falls back to a default when the variable is not set.
- Describe EVs once. Name a set of EV parameters under
evs: and plug it in with plugyard exec FAST-1 plug --ev longrange.
- Charge like a fast-charging car.
curve: dc-fast in an EV preset, or plug --curve dc-fast, makes power ramp up, hold, and taper off as the battery fills.
- Speed time up.
plugyard site up --speed 60 makes one real second count as a minute of charging.
- Go easy on the CSMS.
--connect-rate 50 opens at most fifty new connections a second; by default every charger connects at once.
All of it is specified in docs/SPEC.md, sections 5 to 7.
One charger, no site file
plugyard run Chargerfile --csms ws://localhost:9000/ocpp --id CP-1
It runs in the foreground until you press Ctrl+C. Add -d to run it in the background; plugyard stop CP-1 then shuts it down. Its state is saved too: run the same --id again and the same charger comes back. Add --rm for a throwaway charger that saves nothing, and --password (or set PLUGYARD_CSMS_PASSWORD) for Basic Auth over wss://.
With an AI agent
Coding agents such as Claude Code and Codex can drive plugyard for you: start chargers, plug in, tap, and check what your CSMS answered.
Give the agent the skill. In your project folder:
plugyard init --agents
This installs the plugyard skill with the skills tool, so an agent that opens a session there knows plugyard without being told. In an empty folder it also writes the starter files; in a folder that has them it only adds the skill.
- It runs
npx skills add Amraa1/plugyard, which you can also run yourself. That needs Node.js.
- The skills tool asks which agents you use, and puts the skill where each of them looks.
- The skills tool counts installs anonymously. Set
DISABLE_TELEMETRY=1 to turn that off.
- No Node.js? Copy
skills/plugyard into .claude/skills/ (Claude Code) or .agents/skills/ of your project.
Or just tell it. An agent that has no skill needs one sentence: "use plugyard; run plugyard agents first". That command prints a guide written for agents, matching the version you have installed. The same guide is llms.txt.
How many chargers
One site of 2,000 chargers runs comfortably on a laptop. In the project's own test, 2,000 chargers connected in about one second, each ran a transaction with meter values, and all shut down cleanly, using under 400 MB for the site and the test CSMS together. The figures are in docs/SPEC.md, section 9.
Your CSMS may want them to arrive more gently: plugyard site up --connect-rate 50 opens at most fifty connections a second.
What plugyard does not do
- OCPP 2.0.1; only OCPP 1.6J
- Local authorization lists and reservations; the charger answers these
NotSupported
- Real firmware downloads; the charger reports the statuses and fetches no file
- SFTP uploads that log in with a key; a password in the location is the only way
- Deliberately broken messages, to test how a CSMS handles protocol violations
- Client certificates (security profile 3)
Building from source
Requires Go 1.26 or newer.
go build .
./plugyard version
go test ./...
PLUGYARD_SCALE=2000 go test -run TestScale -v ./internal/cli runs the 2,000-charger test. A release is made by pushing a version tag such as v0.2.0; GoReleaser then builds and publishes the six archives.
Documentation
License
Apache-2.0