winunitd
Declarative Windows unit manager and process supervisor.
The immediate target is a usable public beta, with the
documented unit syntax preserved across beta updates.
The roadmap, Design v2, and implementation milestones
retain the longer-term work. License and copyright notice: MIT.
The MSI installer plan covers packaging, service readiness, upgrades, rollback, signing, and migration from existing installations. No MSI is shipped yet.
Use the pinned build and maintenance workflow for qualification artifacts and their source/hash manifests.
The architecture review records the original findings;
R1 and R2 record implemented fixes.
The archived first design preserves section references in existing source comments.
Binaries
| Binary |
Role |
winunitd.exe |
Daemon: loads units and supervises processes |
winctl.exe |
Control CLI for the daemon |
winunit-notify.exe |
Helper for units to report ready / status |
Windows is the first-class target (GOOS=windows).
Status
0.1.0-alpha (winctl --version / winunitd --version).
Implemented today: unit loader, dependency graph and start transactions, JSON-RPC control API, SCM host, Job Objects, restart policies, enable/targets at boot, journal, internal timers, ordered stop, per-user managers and lingering, Type=notify / watchdog, Type=scm and Type=scheduled-task proxies, Job Object resource limits, and .registry / .eventlog / .path companions. Details below.
Planned in this iteration: lifecycle ownership fixes, a single coordinator, versioned unit semantics, ExecStop, qualified user launching, durable scheduling, and MSI servicing. Deferred: CTRL_BREAK / WM_CLOSE, GUI attach, SessionPolicy, arbitrary credential brokering, and WatchdogMode=window — see ROADMAP.md.
Build
Qualification builds use the Go version pinned in .go-version.
No product MSI is shipped yet.
go test ./...
GOOS=windows go build -o winunitd.exe ./cmd/winunitd
GOOS=windows go build -o winctl.exe ./cmd/winctl
GOOS=windows go build -o winunit-notify.exe ./cmd/winunit-notify
On Windows, GOOS=windows is implicit. From cmd.exe use set GOOS=windows; from PowerShell, $env:GOOS="windows". Cross-compile from Linux/macOS with the GOOS=windows prefix. Tests stay on the host OS (go test ./...).
Install / run
- Copy the three binaries somewhere permanent (install does not set PATH).
- Register and start the system daemon:
winunitd install
sc start winunitd
winunitd install registers winunitd (DisplayName WinUnit Manager) as LocalSystem, Automatic (Delayed Start). Tear down with winunitd uninstall / sc stop winunitd.
- Drop unit files under
C:\ProgramData\winunitd\units\ (created on install). Journals and enable links live under the same tree (journal\, enabled\, runtime\, linger\).
- Talk to the system manager:
winctl list-units
winctl enable foo.service
winctl start foo.service
winctl status foo.service
- Per-user:
winctl --user … on \\.\pipe\winunitd\user\<SID>\control. User units live under %LOCALAPPDATA%\winunitd\units\.
Console mode without SCM: winunitd --base-dir DIR.
Windows Service
winunitd install [--base-dir DIR]
winunitd uninstall
Install creates C:\ProgramData\winunitd (units\, enabled\, journal\, runtime\, linger\) if missing, sets SCM recovery to restart on failure, and accepts preshutdown for ordered stop. It does not add PATH or register an Event Log provider.
On start (SCM or console) the daemon starts builtin default.target, which Wants=timers.target. Built-in targets: default.target, timers.target, shutdown.target (network-online.target is not shipped). A user manager also loads graphical-session.target.
The daemon creates a Job Object with KILL_ON_JOB_CLOSE: if winunitd.exe is killed, assigned children die with it. Each started unit gets its own nested Job Object (no breakaway). On sc stop, preshutdown, or console SIGINT, units stop in reverse After=/Before= order (shutdown.target as the stop root), then the daemon Job Object closes.
winctl daemon-reload reparses units and rebuilds the graph without dropping live jobs.
Invalid files or an ordering cycle reject the entire candidate; the previous
accepted definitions and graph remain usable. A rejected cold load starts no
candidate units. A valid removal retains a live unit as LoadState=unavailable
for status/log/stop access and suppresses future activation until its definition
returns. Reload errors and cycle diagnostics are returned by daemon-reload.
Machine and unit status report ConfigRevision; service status also reports
InvocationConfigRevision for its last captured service invocation. Reload and
enablement graph acceptance produce a new opaque ID, including unchanged-content
reloads. Running services and automatic recovery keep their captured ID; a new
explicit start adopts the accepted one. A removed unit has no loaded revision,
but its last invocation revision remains available. IDs are scoped across daemon
instances and do not expose configuration content.
Timer and native-watch status report ArmedConfigRevision until disarm/cleanup.
Reload keeps that captured ID; a fresh arm adopts the accepted revision.
list-timers reports the armed companion when a timer remains armed across reload.
Control API
Versioned JSON-RPC on \\.\pipe\winunitd\control (LocalSystem and Administrators). Production Peer comes from the named-pipe client token. Pipes use PIPE_REJECT_REMOTE_CLIENTS and first-instance-only; winctl verifies the server process owner after connect and refuses a squat.
winctl --user … and winctl <command> --user both use \\.\pipe\winunitd\user\<SID>\control. Bare winctl stays on the system pipe. Linger admin verbs do not use --user.
winctl commands
start, stop, restart, status, operation, enable, disable, list-units, list-timers, logs, daemon-reload, enable-linger, disable-linger, verify.
winctl status UNIT exit codes are systemctl-shaped: 0 active, 3 loaded but inactive/failed, 4 not loaded. Transport/protocol errors keep their existing non-zero exit. Machine status (no unit) exits 0 on success.
Start/stop/restart replies and admitted failures include OperationID; unit
status exposes LastOperationID. Use winctl operation ID to query that
transaction's outcome independently of current unit state. The manager retains
pending operations and its latest 256 completed records; history resets when
the manager exits. See operation history for admission
budgets, query exit codes, compatibility, and current limits.
Enable links
winctl enable writes files under <base-dir>\enabled\<target>\<unit> (not NTFS symlinks). A fresh daemon start pulls in enabled Wants=/Requires= only.
Unit files
Verify
winctl verify parses a systemd-like INI unit and checks MVP rules. It does not need a running daemon when given a file path:
winctl verify C:\path\foo.service
winctl verify C:\path\foo.timer
winctl verify C:\path\foo.registry
winctl verify C:\path\foo.eventlog
winctl verify C:\path\foo.path
Unknown directives are errors. ExecStart= must be an absolute Windows path (SearchPath=no). An omitted WorkingDirectory= is a warning (System32 is not the default). Environment= values are literals (${} is not expanded).
Path vs unit name: a name with no /, \, or drive prefix is always a unit name, even if a same-named file exists in the cwd. Use ./foo.service, .\foo.service, C:\path\foo.service, or winctl verify --file foo.service (-f). Mixing unit names and paths in one invocation is a usage error. winctl verify foo.service (unit name) talks to the daemon.
Restart and start limits
Restart= supports no / always / on-failure / on-watchdog.
[Unit] StartLimitIntervalSec= / StartLimitBurst= default to 10s / 5. StartLimitBurst=0 is unlimited. Burst starts inside the interval fail with reason start-limit. Timer/watch activations and automatic recovery share this budget; a redundant activation of an already-running process does not consume another start. Explicit winctl start resets the limit.
RestartMaxDelaySec= and RestartBackoff= are not parsed.
The daemon admits up to 32 simultaneous start transactions, with up to 16
concurrent adapter calls per transaction. Excess operator starts report capacity
exhaustion and may be retried. Explicit stops use a separate 32-transaction
budget; shutdown bypasses both budgets. Native watch activations
wait for capacity; timer activations retry without consuming a second deadline.
These pending retries are not yet durable across a daemon crash.
Invocation IDs
Each unit start (including Restart= relaunch) gets a new UUID. winctl status prints InvocationID=. Journal lines for that run carry the same ID. The process env includes WINUNIT_INVOCATION_ID.
Notify and watchdog
Type=notify stays activating until the unit writes READY=1 on WINUNIT_NOTIFY_PIPE (\\.\pipe\winunitd\notify\<unit>), or TimeoutStartSec fires. NotifyAccess=main only. Scripts send READY / WATCHDOG / STATUS with winunit-notify.exe.
The current alpha notify transport sends a WINUNITD-NOTIFY/1 line from the server before the client writes its payload. Clients must read this acceptance banner before sending and closing, preventing a short-lived Windows pipe connection from being discarded before acceptance. The banner is not a readiness acknowledgement. Upgrade winunit-notify.exe and the daemon together: older daemons do not send it, so the current helper will time out against them. Custom clients should adopt the handshake; legacy write-only clients retain the early-disconnect risk.
| Mode |
Behavior |
WatchdogMode=notify (default with WatchdogSec=) |
Injects WINUNIT_WATCHDOG_USEC; missed heartbeat fails the unit |
WatchdogMode=tcp |
Connect-only on WatchdogEndpoint= (127.0.0.1:port or [::1]:port) |
WatchdogMode=http |
GET WatchdogEndpoint= (http://127.0.0.1:...); expects WatchdogExpectedStatus= (default 200) |
TCP/HTTP endpoints must be loopback; non-loopback is a parse error and is never dialed. A missed or failed probe fails the unit (failed / watchdog), then Restart= (including on-watchdog).
Resource limits (Job Object)
Limits apply on the existing per-unit job. Hitting MemoryMax= or ProcessLimit= fails the unit with reason resource-limit on winctl status; Restart= still applies.
| Directive |
Semantics |
MemoryMax= |
Job-wide commit cap (K / M / G) |
ProcessLimit= |
Active processes |
PriorityClass= |
idle / below-normal / normal / above-normal / high (not realtime) |
CPUWeight= |
1–10000 → Windows job weight 1–9 as clamp(1, 9, (CPUWeight + 1110) / 1111) |
CPUQuota= |
N% with N in 1–100 = percentage of total machine CPU → CpuRate = N * 100 (Windows max 10000; not systemd per-CPU) |
IoPriority= |
idle / low / normal / high via NtSetInformationProcess after job assignment |
CPUWeight= and CPUQuota= cannot both be set. Job Objects have no I/O-priority class; a failed IoPriority= set fails activation with reason configuration. These are Windows Job Object semantics, not cgroup cpu.weight / cpu.max / io.weight.
winctl verify rejects bad sizes, ProcessLimit=0 or negative, unknown PriorityClass= (including realtime), CPUWeight= outside 1–10000, CPUQuota= without % or N outside 1–100, both CPU keys together, unknown IoPriority=, and those keys on .timer / .target.
Proxy unit types
Type=scm — system-manager proxy for an existing SCM service (ServiceName= required, e.g. MSSQLSERVER). Maps StartService / StopService / QueryServiceStatusEx to ActiveState. Already running/stopped is success. No CreateProcess, Job Object, ExecStart, notify pipe, WINUNIT_* env, or WatchdogMode. Timeouts wait for SCM state. Restart= applies to start failure only; winunitd does not watch the service after it reports running. Invalid in a user unit. Does not register or edit SCM configuration (not import-service).
Type=scheduled-task — system-manager proxy for an existing Task Scheduler task (TaskName= required, e.g. \Backups\LegacyBackup). Native .timer is preferred for new schedules; this type is legacy interop. Maps IRegisteredTask.Run / Stop / State to ActiveState. Same constraints as Type=scm (no process ownership, no watchdog; Restart= on start failure only). Invalid in a user unit. Does not create or edit the task definition (not import-task).
After=/Requires=/Wants= work so a native unit can wait until the proxy reports running.
Companion units
Companions start foo.service by basename. Unit= is not accepted. The companion .service must sit next to the companion file.
| Type |
Trigger |
Notes |
.registry |
[Registry] RegistryChanged=HKLM\… or HKCU\… |
Key+subtree via RegNotifyChangeKeyValue. Missing key → reason configuration. System-scope verify rejects HKCU; winctl --user verify accepts HKCU and HKLM. |
.eventlog |
[EventLog] EventLogTrigger=<Channel>:EventID=<uint16> |
Via EvtSubscribe. Subscribe failure or unknown channel → reason configuration. winctl --user verify rejects System and Security. |
.path |
[Path] PathChanged= (absolute, repeatable OR) and/or PathExists= (absolute, repeatable AND — lock vs systemd OR) |
Mix: either may start. ReadDirectoryChangesW non-recursive; a file path watches the parent and filters by name. Bad PathChanged= → reason configuration; missing PathExists= waits for creation. |
Timers
Internal scheduler (not Task Scheduler). OnBootSec is since machine boot; OnStartupSec is since this winunitd instance. A foo.timer activates foo.service when Unit= is omitted.
winctl list-timers / status show next/last elapse when a timer is active. Calendar Next is recomputed after a wall-clock jump (Engine.ClockChanged, driven by SCM SERVICE_CONTROL_TIMECHANGE and SERVICE_CONTROL_POWEREVENT / PBT_APMRESUMEAUTOMATIC). Console mode has no WM_TIMECHANGE window; a 30s poll is the fallback. Timer last-run state lives under <base-dir>\runtime\timers\.
Journal and logs
stdout/stderr are stored under <base-dir>\journal\<encoded-unit>.log (system: C:\ProgramData\winunitd\journal\; user: %LOCALAPPDATA%\winunitd\journal\). Current file capped at 10 MiB with 3 rotated generations (.log.1 … .log.3). Filenames percent-encode Windows-forbidden characters. The writer timer-flushes; Sync runs on unit exit, daemon shutdown, and rotate — not per line.
Records are JSON lines with v=3 (continuation, partial, severity, session, userSid, plus timestamp/unit/pid/stream/message/invocationId). Captured stdout/stderr messages are split at UTF-8 boundaries into fragments of at most 64 KiB; JSON escaping can expand the stored record. continuation=true joins the preceding fragment for the same invocation and stream; partial=true means the fragment has no terminating newline, including an unterminated final line. These fields are also exposed by the logs API. Severity from stream: stdout→info, stderr→err. Readers accept mixed v=1/v=2/v=3 and do not rewrite old lines. Older readers may display fragments as separate lines.
Capture uses a bounded writer queue: at most 4 MiB of pending message data per invocation, 16 MiB per store, 12,288 pending fragments per invocation, and 16,384 queued fragments overall. The per-invocation record cap prevents one stream of short lines from consuming the entire shared queue. These limits exclude stream read buffers, per-unit flush buffers, record metadata, JSON expansion, and other manager memory. The single writer preserves enqueue order; blocked storage can affect every unit's journal, but capture keeps draining and rejects new fragments when a limit is reached.
Unit status exposes cumulative logDroppedRecords, logDroppedBytes (normalized message bytes, excluding line endings), logStorageErrors, and logLastStorageError. Counters reset with the manager. Drop counters cover rejected fragments and pending records abandoned by a failed close. Sync failures or external file damage can lose additional data. Do not treat continuation metadata as proof of a complete line after loss.
Journal waits honor their context during capture and sync; close waits up to five seconds, returns an error on timeout, and retains file ownership for cleanup if storage recovers. After an interrupted append, reopening the journal adds a missing newline before new records and reports the repair; existing bytes are preserved. During a live write failure, each file retains the exact unwritten suffix of its current batch (at most 4 KiB or one larger serialized record) and retries with a 1 to 30 second backoff. New records for that file are rejected and counted while recovery is pending. A recovered write resumes without reopening or duplicating the retained record. Actual volume exhaustion and automatic recovery passed on a disposable Server Core baseline copy; see R1 evidence. Fairness under aggregate overload remains pending.
winctl logs UNIT [--follow] [--since <when>]
--since is a lower bound (RFC3339, YYYY-MM-DD, Go duration such as 1h, or 1 hour ago); a bad value is an error. --follow polls new lines with a cursor over the existing logs RPC (no streaming). --boot is not implemented.
Log responses are paginated below the 1 MiB RPC limit. winctl logs reads every page, including without --follow. API clients should request the returned cursor while more is true. A single entry too large for a response returns an explicit error. Each query has a five-second deadline, and at most four queries per store may occupy storage workers. A timed-out native read or flush retains its slot until it returns; further queries receive a capacity error when all four slots are occupied. Cancellation preserves the supplied cursor. These limits bound requests and workers; they cannot interrupt an underlying Windows filesystem call.
User managers and linger
Interactive user managers require admission. The default admits only administrator-enabled users in <base-dir>\user-admission.json; a missing file admits none. Administrators may instead select unit-files mode to delegate admission to user unit-file presence. Explicit per-SID disable overrides delegation. See configuration and qualification limits.
For an admitted interactive user the system manager launches winunitd --user-manager <SID> (same binary, not an extra SCM service) using WTSQueryUserToken. One manager per SID. System list-units does not show user units. Policy and existing sessions are reconciled every ten seconds; explicit changes also invalidate pending admission results.
User units load from %LOCALAPPDATA%\winunitd\units\. User processes get a deterministic environment (USERPROFILE, LOCALAPPDATA, APPDATA, TEMP, TMP, USERNAME, USERDOMAIN).
Each user manager watches WTS for its SID and starts builtin graphical-session.target while that SID has a suitable interactive session (Inactive when none, including linger-without-session). RequiresInteractiveSession=yes skips that unit when no suitable interactive session exists (SessionMode is not implemented).
Administrators can winctl enable-linger <user> on the system pipe (not --user). Linger state is a tiny record at <base-dir>\linger\<SID> (not an NTFS symlink). At boot, lingering user managers start with no session. Last logoff does not kill a lingering manager; disable-linger kills it if no session remains. Non-admin enable-linger fails closed.
S4U uses a trusted LSA connection (LsaRegisterLogonProcess; LocalSystem has SeTcbPrivilege). An optional named CredMan/LSA URI on the linger record is used only if present and S4U is insufficient for outbound network creds. That fallback calls LogonUserW with LOGON32_LOGON_BATCH (never a password in a unit file, env, or path). The daemon logs which path produced the token (s4u vs store-uri).
Unverified
Unit tests and GitHub Actions go test ./... on windows-latest are not a live production Windows proof. These paths are implemented; they have not been signed off on a real machine in the conditions below. Silence is not verification.
- Job CPU/I/O —
CPUWeight= / CPUQuota= and IoPriority= are unit-tested (set + query back). Live throttling and I/O-class effect under load are unverified.
- EvtSubscribe —
.eventlog subscribe + Application ReportEvent tests exist. Production channel rights, Security, and custom logs on a real host are unverified.
- ReadDirectoryChangesW —
.path watches fire in unit tests on temp directories. Long-lived, network, reparse-point, and volume-unmount behavior is unverified.
- Lingering-child journal — journal wait is bounded by
TimeoutStopSec (#83). That linger-and-abandon path on a live Windows host is unverified.
- Admin vs non-admin pipe Peer / elevated
winctl --user — token Peer and DACL tests exist. UAC-filtered vs elevated token on the user pipe is unverified. CI runners are typically already Administrators.
- Live SYSTEM S4U —
TestSYSTEMLingerTokenDuplicatePrimaryAndCreateProcessAsUser skips unless LocalSystem (psexec -s). GitHub Actions windows-latest is not SYSTEM.
- SCM TIMECHANGE / POWEREVENT — the service accepts those controls. Live delivery to a running service (calendar
Next recompute) is unverified. Console mode falls back to a 30s poll.