mbus

module
v0.2.0 Latest Latest
Warning

This package is not in the latest version of its module.

Go to latest
Published: Oct 11, 2026 License: Apache-2.0

README

mbus

Wired M-Bus, Wireless M-Bus and OMS in pure Go: a bus master, a telegram decoder with every security mode, data records with OBIS codes, and the M-Bus adaptation layer for LPWAN.

Go Reference test Go

The wired master follows the EN 13757-2:2018+A1:2023 link layer and the EN 13757-3:2025 procedures: frame count bits per address, repeats and answer timing, primary and secondary selection, the wildcard search with collision handling, multi-telegram reads, alarms, clock synchronisation, baud rate switching and image transfer. The wireless side decodes EN 13757-4 frames and the EN 13757-7:2025 and OMS security layers (ELL, AFL, TPL; security modes 2, 3, 5, 7 to 10 and 13; SITP; compact frames), reads and configures iM871A, Amber and CUL receiver sticks and reads rtl-wmbus, and schedules downlinks into meters' receive windows with their response delays. One decoder of data records serves both, with the annex H translation to OBIS codes, and per-meter drivers read the manufacturers' own payloads (Techem, Apator, Diehl/IZAR, Qundis, BFW, Zenner and others) and name 90 more meter models. No cgo. It was written for SigmaM2M, a oneM2M platform, where it serves its wired M-Bus, Wireless M-Bus, LoRaWAN and raw-payload integrations, and has no dependency on it.

Features

Area Implemented Not implemented
Wired link (EN 13757-2:2018+A1:2023) FT1.2 frames, ACK/NACK, SND_UD2, the frame count bit per address (A1 rules), three attempts, the answer window, an idle line after broadcasts, collisions in the search, management frames to the primary master repeater (address 251, Master.Repeater) Named repeater commands: the standard reserves address 251 but leaves its commands to each repeater's maker; the physical layer (a level converter does it)
Wired application (EN 13757-3:2025) Variable and fixed data, multi-telegram reads, alarms, application select and reset, set primary address (with a lost-ACK check), baud rate switching, clock synchronisation (types I, J, M), synchronize, application errors, image transfer (annex I), DLMS behind CI 60h/61h and 7Ch/7Dh, transport PDUs Manufacturer-specific procedures
Data records Every DIF/VIF of clause 6 and annex C, combinable VIFEs, LVAR, dates and times (types F, G, I, J, K, L, M), compact profiles (annex F), annex H OBIS codes, manufacturer codes, device types, TPL status flags; a standard VIF followed by a manufacturer VIFE also decoded as the VIF says (Record.BaseValue) Legacy Fahrenheit codes keep their code (no unit)
Meter drivers (meters) Manufacturers' own payloads: Techem compact V, vario 4, radio 3 and 4, FHKV data III, smoke detector; Apator 08, 17-2, AT-WMBUS-16-2, E-ITN, NA-1 (AES); Diehl/Hydrometer/Sappel PRIOS (IZAR) and "real data" scrambling, with keys the caller supplies (SetMakerKeys or the meter's key; the library ships no keys); BFW 240 radio; Zenner 0Bh; Qundis walk-by records (Q water, Q heat, Q caloric); B METERS RFM-TX1's clock; 90 more models named from their M, version and device type; device types makers use outside the standard mapped; Register adds or overrides drivers The volume of the B METERS RFM-TX1 (obfuscated with a table we know no public description of); further manufacturer fields of meters whose standard records already decode (see the interop results)
Wireless link (EN 13757-4:2025) Formats A and B, CRCs, 3-out-of-6, mode F FEC, C fields, relayed (H) and repeated frames, duplicates; compact frames whose Full-Frame-CRC fails can be accepted with a warning (FormatCache.IgnoreFullFrameCRC, off by default) The radio (a receiver stick does it)
Security (EN 13757-7:2025, OMS) Modes 2, 3 (DES, deprecated; mode 2 optionally checked by its 2F2F fillers as wmbusmeters does, Decoder.DESCheck2F2F), 5, 7, 8, 9, 10, 13; ELL encryption; AFL MACs and fragments; KDF-A; counters and replay detection; SITP (annex A) both ways; OMS security profiles A to D (C: mode 13 TLS, annex F); sealing for meters and gateways; the payload of a maker's own security mode or CI field kept for the drivers
Receivers iM871A (HCI with CRC, RSSI, timestamp), Amber command mode, CUL/nanoCUL (culfw), rtl-wmbus text, raw L framing, hex lines; setting the radio mode of iM871A, Amber and CUL sticks (ConfigureIM871A, ConfigureAmber, ConfigureCUL); a downlink Scheduler (one downlink per receive window, answers matched by access number, frames timed into the response delay of modes S, T and C, slow or fast by the D bit) Radiocrafts and Embit sticks' native protocols; response delays of modes R, N and F
MBAL (EN 13757-8) The control field and the LoRaWAN, UDP, CoAP/COSE/CBOR, MIOTY and Wize layouts Network handling (the caller's)
DLMS over M-Bus (EN 13757-1:2021) Transport PDUs (tpdu); with dlms's cosem, DLMS APDUs inside M-Bus

Choosing an M-Bus library

Compared from each project's source at the versions named, in October 2026. Cells marked "not checked" were not verified in the source. Check the projects themselves before relying on a row.

this module gombus v1.1.0 (Go) wmbusmeters 3.0.0 (C++) libmbus 0.10.3 (C)
Licence Apache-2.0 Apache-2.0 GPL-3.0-or-later BSD-3-Clause
What it is Go library Go library and a command a program (daemon and command line) with meter drivers C library and commands
Wired master: search, secondary addressing, multi-telegram reads yes, with collision handling, frame count bits per address, repeats yes (scan, secondary addressing, readdressing) not checked yes
Wired procedures: alarms, baud switch, clock sync, image transfer, application select and reset yes not checked not checked partial (not checked in detail)
Wireless decoding: formats A and B, CRCs yes, and 3-out-of-6 and mode F FEC yes yes no
Security modes 2, 3, 5, 7, 8, 9, 10, 13; ELL and AFL; SITP; Diehl scrambling 0, 5, 7 (13 refused) 5, 7, ELL AES-CTR, DES mode 2, Diehl scrambling; others not checked none
Compact frames, OMS profiles A to D yes not checked compact frames yes; profiles not checked no
Receiver sticks iM871A, Amber, CUL, rtl-wmbus, raw, hex; setting iM871A, Amber and CUL modes; a downlink scheduler none (takes the telegram) many dongles, including iM871A, Amber, CUL, RC1180, rtl-sdr (rtl-wmbus and rtl_433) serial and TCP for wired
Per-meter drivers (manufacturers' own payloads) 20 drivers of manufacturer data and 90 more models named (every manufacturer payload of wmbusmeters' tests but one meter's volume; see below) no over a hundred, with more manufacturer fields per meter no
OBIS codes (EN 13757-3 annex H), MBAL (EN 13757-8) yes no no no
cgo / runtime none, pure Go none, pure Go a C++ program C (cgo from Go)

Pick this module for a Go gateway or head end that needs the security modes beyond 5 and 7, OMS profiles, receiver sticks, downlinks, OBIS codes or MBAL, without cgo; its drivers read every manufacturer payload in wmbusmeters' test data but one. Pick wmbusmeters when you need a ready daemon, its wider range of receivers (RC1180, rtl_433), or the manufacturer fields it reads beyond the standard records for meters such as Waterstar M, B METERS Hydrodigit and Schneider iEM3000 (about 430 of the 3,264 values its tests print are not among ours, see below). Pick libmbus for wired M-Bus from C, and gombus for a small Go wired master with plain or mode 5 and 7 wireless decoding.

Install

go get github.com/cB-Sigma/mbus@latest

Requires Go 1.27.1 or later (tlsx, the TLS of security mode 13, needs it).

Quick start

import (
	"github.com/cB-Sigma/mbus/meters"
	"github.com/cB-Sigma/mbus/wired"
	"github.com/cB-Sigma/mbus/wireless"
)

// Wired: a converter on TCP (wired.OpenSerial for a local port).
conn, _ := net.Dial("tcp", "192.0.2.20:10001")
m := wired.NewMaster(2400)
m.SetPort(wired.NewPort(conn), 2400)
found, _ := m.Search(ctx)
a, _ := m.Select(ctx, wired.Target{Secondary: &found[0]})
m.ReadTelegrams(ctx, a, 8, func(t wired.Telegram) error {
	for _, r := range t.Records {
		fmt.Println(r.Name(), r.Value, r.Unit) // volume 12.345 m3
	}
	return nil
})

// Wireless: one telegram, with the meter's key, read with its driver.
keys := func(wireless.Header) []byte { return key }
tg, err := wireless.Decode(frame, wireless.FormatNoCRC, keys)
r, err := meters.ReadKeys(tg, err, keys) // r.Driver "techem-compact5", r.Float("energy")

The examples that run and check their output are wired.ExampleFrame_Encode, wireless.ExampleDecode, records.ExampleParseRecords, tpdu.ExampleSegmentAPDU and mbal.ExampleParseUDP. wired.ExampleMaster needs a bus, so it compiles but does not run here; mbus-sim runs the same steps against its simulated bus.

Documentation

API reference: https://pkg.go.dev/github.com/cB-Sigma/mbus

Package What it does
wired FT1.2 frames; Master (frame count bits, repeats, selection, SelectOne, the search, multi-telegram reads, REQ_UD1, application select and reset, set primary address, baud switch, clock synchronisation, image transfer, frames to the repeater at address 251); responses with variable or fixed data, application errors, DLMS APDUs; Port over a serial port (8E1) or a TCP converter
wireless Frame formats, CRCs, 3-out-of-6, FEC; Decode/Decoder (ELL, AFL, TPL, security modes, replay detection, SITP, compact frames with FormatCache); SealTPL, SealAFL, EncodeDownlink; Reader for iM871A, Amber, CUL, rtl-wmbus, raw and hex receivers; ConfigureIM871A, ConfigureAmber, ConfigureCUL; Scheduler with ResponseDelay; TLS endpoints of mode 13
records Data records, names and UCUM units, compact profiles, OBIS codes (annex H), manufacturer codes, device types, status flags
meters Per-meter drivers: Read/ReadKeys a decoded telegram into named values, Lookup, Register, Drivers, SetMakerKeys and DefaultKey (makers' default keys, supplied by the caller; none ship)
tpdu DLMS/COSEM transport PDUs over M-Bus (EN 13757-1:2021 8.2.4)
mbal The MBAL control field and the LoRaWAN, UDP, CoAP/COSE/CBOR, MIOTY and Wize layouts (EN 13757-8)

Testing

go test -race ./...

The tests use the worked examples of the standards (EN 13757-3:2025 annexes F and G), every example frame of OMS Specification Volume 2 annex N with its keys, the example telegrams of the M-Bus documentation, four heat meter answers from libmbus's test suite (BSD-3-Clause, see NOTICE), RFC 3610, 4493 and 5649 vectors, and fuzzing of the wired frame, record and MBAL decoders. The meter drivers' unit tests build telegrams in each layout with values of their own; the stick commands are tested against byte vectors and a fake stick on a pipe. Tests carry // Covers: SIG-... comments: requirement IDs of the SigmaM2M project's compliance report, which mean nothing else here.

The master's tests against a simulated bus are in mbus-sim, so this module does not depend on its simulator.

Interop tested against

Against the published test data of two independent implementations, on 2026-10-11 (interop/, a nested test-only module that fetches the data at run time and keeps none of it here; cd interop && SIGMA_MBUS_INTEROP=1 go test -v ./...).

Peer and data Result
libmbus 0.10.3 (commit d617bd2), every frame of test/test-frames, compared record by record with libmbus's normalised XML 76 of 76 frames decoded; headers 75 equal, 1 different (M field 0000h printed as 0000, libmbus prints @@@); records 942 compared, 927 equal (the 21 records with a manufacturer VIFE after a standard VIF compared by BaseValue), 15 different, every difference explained: 9 values coded invalid (we mark them, libmbus prints the digits), 4 combinable VIFEs (limit-exceed durations) that we apply and libmbus ignores, 1 "every year" date, 1 VIF with no defined meaning
wmbusmeters 3.0.0 (commit ac4f295), the telegrams of its driver tests and simulation files with the keys they give, compared with the JSON wmbusmeters prints 403 frames (364 wireless, 39 wired); 396 decoded as the library ships (398 with the opt-in FormatCache.IgnoreFullFrameCRC, see below), 54 of them by a meter driver (meters): 47 of the 48 proprietary payloads (the 48th is the too-short telegram below), the 4 manufacturer-specific CI fields and the 3 Diehl telegrams (one scrambled, unscrambled with a default key; two stored unscrambled, read with AcceptPlainDiehl), with the Diehl default keys the test reads from the wmbusmeters checkout and passes to SetMakerKeys; the DES telegram decodes with DESCheck2F2F. Meter ID 381 equal, 0 different; medium 377 equal, 0 different. Every numeric field and date wmbusmeters prints, looked for among our reading's values of the same unit (names differ between the projects, so by value): 3,264 compared, 2,840 found, 424 not (with the lenient option on; they are fields the wmbusmeters drivers read from manufacturer data or compute, listed per driver by the test, the largest Waterstar M, B METERS Hydrodigit and Hydroclima, Schneider iEM3000 and Qundis Q heat monthly deltas); 71 more are dates coded invalid that wmbusmeters prints as dates (years past 2100, month 15), not compared. The frames not decoded are listed below.

The 7 wmbusmeters frames the library does not decode by default:

Telegram (wmbusmeters file:line) Reason Decodes with
generated_tests.xmq:1337 (Kamstrup flowIQ 2200 compact frame) rebuilt with the format wmbusmeters' driver lists, the records fail the frame's Full-Frame-CRC, which wmbusmeters does not check FormatCache.IgnoreFullFrameCRC (with a warning); values then equal wmbusmeters'
simulation_formulas.txt:1 (Kamstrup MULTICAL 21 compact frame) the same: the driver's format rebuilds it, the Full-Frame-CRC does not match FormatCache.IgnoreFullFrameCRC (with a warning)
simulation_bad_keys.txt:1 (Techem FHKV data IV) encrypted (mode 5); the test runs it without a key, and with a wrong key, to check wmbusmeters' warnings not decodable without the meter's key; wmbusmeters prints no reading either
simulation_broken.txt:6 and :9 (Engelmann, M field EFE) encrypted (mode 5); the test gives no key, and its comments call the content broken not decodable without the meter's key
simulation_broken.txt:3 its last byte removed on purpose, so the link-layer CRCs fail nothing (broken on purpose)
generated_tests.xmq:2090 (Techem TSD2) the payload is 2 bytes, shorter than the layout nothing; wmbusmeters prints a decoding error for it too

So, with the lenient option on, every frame wmbusmeters reads from the data given is read here too.

These runs found and fixed two decoder bugs: the order of a plain-text VIF's text and its combinable VIFEs as Elvaco meters send them, and the byte order of the extended link layer's payload CRC. wmbusmeters decoding the telegrams of our simulated meter is recorded in mbus-sim. Also tested: the worked examples of the standards and OMS (above).

The meter drivers' layouts were checked only against these published telegrams; the stick commands (iM871A, Amber, CUL) and the rtl-wmbus and CUL readers only against byte vectors and the simulated stick in mbus-sim.

Not yet, each needing hardware or data we do not have: a real meter, receiver stick (to confirm the mode commands and the CUL and rtl-wmbus output) or repeater on a live bus; Radiocrafts and Embit sticks' protocols (no stick to check against); the remaining manufacturer fields above, which need the makers' descriptions or more telegrams with known values; the RFM-TX1 volume (no public description of its obfuscation).

  • mbus-sim: a simulated wired M-Bus segment, wireless meters and receiver sticks.
  • dlms: DLMS/COSEM, whose OBIS model the records use and whose client carries DLMS inside M-Bus.
  • iotcrypto: AES-CCM for security mode 10 and COSE.
  • tlsx: the TLS of security mode 13.

Status

v0.x: the API may change before v1.

Contributing

See CONTRIBUTING.md.

Security

See SECURITY.md to report a vulnerability privately.

Licence

Apache-2.0 (see LICENSE and NOTICE). Copyright 2026 Abhinav Gautam.

Directories

Path Synopsis
Package mbal is the M-Bus adaptation layer (MBAL) of EN 13757-8:2023: the one-byte MBAL control field (optionally introduced by the CI field CFh) that carries M-Bus upper layers (AFL, TPL, APL of EN 13757-7 and -3) over LPWAN technologies, and the per-technology payload layouts of the annexes: LoRaWAN (FPort is the control field, Annex D.6), NB-IoT/LTE-M over UDP or CoAP/COSE/CBOR (Annex C.4), MIOTY (Annex E.5) and Wize (Annex F.4).
Package mbal is the M-Bus adaptation layer (MBAL) of EN 13757-8:2023: the one-byte MBAL control field (optionally introduced by the CI field CFh) that carries M-Bus upper layers (AFL, TPL, APL of EN 13757-7 and -3) over LPWAN technologies, and the per-technology payload layouts of the annexes: LoRaWAN (FPort is the control field, Annex D.6), NB-IoT/LTE-M over UDP or CoAP/COSE/CBOR (Annex C.4), MIOTY (Annex E.5) and Wize (Annex F.4).
Package meters reads Wireless M-Bus telegrams with per-meter drivers: manufacturers' own payloads (a manufacturer-specific CI field, a manufacturer record, a maker's security scheme) and the model of meters whose data records are standard.
Package meters reads Wireless M-Bus telegrams with per-meter drivers: manufacturers' own payloads (a manufacturer-specific CI field, a manufacturer record, a maker's security scheme) and the model of meters whose data records are standard.
Package records decodes the M-Bus application layer that wired and wireless M-Bus share (EN 13757-3:2025): data records with their DIF, DIFEs, VIF and VIFEs (clause 6 and annexes A to C and E), the compact profiles of annex F, the OBIS codes of annex H (on .../libs/dlms/obis), manufacturer codes, device types and the TPL status byte.
Package records decodes the M-Bus application layer that wired and wireless M-Bus share (EN 13757-3:2025): data records with their DIF, DIFEs, VIF and VIFEs (clause 6 and annexes A to C and E), the compact profiles of annex F, the OBIS codes of annex H (on .../libs/dlms/obis), manufacturer codes, device types and the TPL status byte.
Package tpdu is the transport sub-layer that carries DLMS/COSEM APDUs over wired and wireless M-Bus (EN 13757-1:2021 8.2.4): an APDU split into transport PDUs with a fragment counter and FIN, and joined again.
Package tpdu is the transport sub-layer that carries DLMS/COSEM APDUs over wired and wireless M-Bus (EN 13757-1:2021 8.2.4): an APDU split into transport PDUs with a fragment counter and FIN, and joined again.
Package wired is wired M-Bus: the EN 13757-2:2018+A1:2023 link layer (FT1.2 frames, ACK and NACK, the frame count bit per address, repeats, answer timing, collisions) and the EN 13757-3:2025 application procedures of a master: primary and secondary addressing (a command to a meter named with wildcards goes only to one selected meter), the secondary address search, multi-telegram reads, class 1 data and alarms, application select and reset, set primary address, baud rate switch, clock synchronisation and image transfer (annex I); plus the fixed data structure, application errors and DLMS/COSEM responses.
Package wired is wired M-Bus: the EN 13757-2:2018+A1:2023 link layer (FT1.2 frames, ACK and NACK, the frame count bit per address, repeats, answer timing, collisions) and the EN 13757-3:2025 application procedures of a master: primary and secondary addressing (a command to a meter named with wildcards goes only to one selected meter), the secondary address search, multi-telegram reads, class 1 data and alarms, application select and reset, set primary address, baud rate switch, clock synchronisation and image transfer (annex I); plus the fixed data structure, application errors and DLMS/COSEM responses.
Package wireless is Wireless M-Bus and OMS: the EN 13757-4 link layer (frame formats A and B with their CRCs, the 3-out-of-6 code, C fields, radio modes, FEC of mode F), the EN 13757-7:2025 transport and security layers (ELL, AFL with fragmentation, TPL short and long headers, security modes 5 and 7 to 10 and the deprecated DES modes 2 and 3, KDF-A, message counters with replay detection, mode 13 TLS records), security information transfer (SITP, annex A), compact frames (EN 13757-3:2025 annex G), the OMS Volume 2 profiles, the framings of receiver sticks (iM871A, Amber, raw, hexadecimal lines), and frames a gateway sends to bidirectional meters with a scheduler that sends one frame per receive window (Scheduler).
Package wireless is Wireless M-Bus and OMS: the EN 13757-4 link layer (frame formats A and B with their CRCs, the 3-out-of-6 code, C fields, radio modes, FEC of mode F), the EN 13757-7:2025 transport and security layers (ELL, AFL with fragmentation, TPL short and long headers, security modes 5 and 7 to 10 and the deprecated DES modes 2 and 3, KDF-A, message counters with replay detection, mode 13 TLS records), security information transfer (SITP, annex A), compact frames (EN 13757-3:2025 annex G), the OMS Volume 2 profiles, the framings of receiver sticks (iM871A, Amber, raw, hexadecimal lines), and frames a gateway sends to bidirectional meters with a scheduler that sends one frame per receive window (Scheduler).

Jump to

Keyboard shortcuts

? : This menu
/ : Search site
f or F : Jump to
y or Y : Canonical URL