README

Splunk distribution of OpenTelemetry Collector

The Splunk distribution of OpenTelemetry Collector provides a binary that can be deployed as a standalone service (also known as a gateway) that can receive, process and export trace, metric and log data. The Collector is an optional component that currently supports:

The Collector is supported on and packaged for a variety of platforms including:

  • Kubernetes: Helm and YAML
  • Linux: All Intel, AMD and ARM systemd-based operating systems are supported including CentOS, Debian, Oracle, Red Hat and Ubuntu. DEB and RPM packages are also provided.
  • Windows: EXE and MSI

🚧 This project is currently in BETA.

Getting Started

This distribution comes with default configurations which require the following environment variables:

  • SPLUNK_REALM (no default): Which realm to send the data to (for example: us0)
  • SPLUNK_ACCESS_TOKEN (no default): Access token to authenticate requests
  • SPLUNK_BALLAST_SIZE_MIB (no default): How much memory to allocate to the ballast. This should be set to 1/3 to 1/2 of configured memory.

In addition, the following environment variables are optional:

  • SPLUNK_CONFIG (default = /etc/otel/collector/splunk-config_linux.yaml): Which configuration to load.
  • SPLUNK_MEMORY_LIMIT_PERCENTAGE (default = 90): Maximum total memory to be allocated by the process heap.
  • SPLUNK_MEMORY_SPIKE_PERCENTAGE (default = 20): Maximum spike between the measurements of memory usage.

When running on a non-linux system, the following environment variables are required:

  • SPLUNK_CONFIG (default = /etc/otel/collector/splunk-config_non_linux.yaml): Configuration to load.
  • SPLUNK_MEMORY_LIMIT_MIB (no default): Maximum total memory to be allocated by the process heap.
  • SPLUNK_MEMORY_SPIKE_MIB (no default): Maximum spike between the measurements of memory usage.

The following sections describe how to deploy the Collector in supported environments.

Docker

Deploy from a Docker container. Replace 0.1.0 with the latest stable version number:

$ docker run --rm -e SPLUNK_ACCESS_TOKEN=12345 -e SPLUNK_BALLAST_SIZE_MIB=683 \
    -e SPLUNK_REALM=us0 -p 13133:13133 -p 14250:14250 -p 14268:14268 -p 55678-55680:55678-55680 \
    -p 6060:6060 -p 7276:7276 -p 8888:8888 -p 9411:9411 -p 9943:9943 \
    --name otelcol quay.io/signalfx/splunk-otel-collector:0.1.0
Kubernetes

To deploy in Kubernetes, create a configuration file that defines a ConfigMap, Service, and Deployment for the cluster. For more information about creating a configuration file, see the example signalfx-k8s.yaml file on GitHub.

Standalone
$ make otelcol
$ SPLUNK_REALM=us0 SPLUNK_ACCESS_TOKEN=12345 SPLUNK_BALLAST_SIZE_MIB=683 \
    ./bin/otelcol
Linux Installer Script

For non-containerized Linux environments, a convenience script is available for installing the Collector package and TD Agent (Fluentd).

Run the following command on your host. Replace SPLUNK_REALM, SPLUNK_BALLAST_SIZE, and SPLUNK_ACCESS_TOKEN for your environment:

curl -sSL https://dl.signalfx.com/splunk-otel-collector.sh > /tmp/splunk-otel-collector.sh;
sudo sh /tmp/splunk-otel-collector.sh --realm SPLUNK_REALM --ballast SPLUNK_BALLAST_SIZE \
    -- SPLUNK_ACCESS_TOKEN

You can view the source for more details and other options.

Currently, only the following Linux distributions and versions are supported:

  • Amazon Linux: 2
  • CentOS / Red Hat / Oracle: 7, 8
  • Debian: 8, 9, 10
  • Ubuntu: 16.04, 18.04, 20.04

Sizing

The OpenTelemetry Collector can be scaled up or out as needed. Sizing is based on the amount of data per data source and requires 1 CPU core per:

  • Traces: 10,000 spans per second
  • Metrics: 20,000 data points per second

If a Collector handles both trace and metric data then both must be accounted for when sizing. For example, 5K spans per second plus 10K data points per second would require 1 CPU core.

The recommendation is to use a ratio of 1:2 for CPU:memory and to allocate at least a CPU core per Collector. Multiple Collectors can deployed behind a simple round-robin load balancer. Each Collector runs independently, so scale increases linearly with the number of Collectors you deploy.

The Collector does not persist data to disk so no disk space is required.

Advanced Configuration

Command Line Arguments

Following the binary command or Docker container command line arguments can be specified. Command line arguments take priority over environment variables.

For example in Docker:

$ docker run --rm -e SPLUNK_ACCESS_TOKEN=12345 -e SPLUNK_BALLAST_SIZE_MIB=683 \
    -e SPLUNK_REALM=us0 -p 13133:13133 -p 14250:14250 -p 14268:14268 -p 55678-55680:55678-55680 \
    -p 6060:6060 -p 7276:7276 -p 8888:8888 -p 9411:9411 -p 9943:9943 \
    --name otelcol quay.io/signalfx/splunk-otel-collector:0.1.0 \
        --log-level=DEBUG

Use --help to see all available CLI arguments.

Custom Configuration

In addition to using the default configuration, a custom configuration can also be provided. Use the SPLUNK_CONFIG environment variable or the --config command line argument to provide a custom configuration.

Command line arguments take precedence over environment variables. This applies to --config and --mem-ballast-size-mib.

For example in Docker:

$ docker run --rm -e SPLUNK_ACCESS_TOKEN=12345 -e SPLUNK_BALLAST_SIZE_MIB=683 \
    -e SPLUNK_REALM=us0 -e SPLUNK_CONFIG=/etc/collector.yaml -p 13133:13133 -p 14250:14250 \
    -p 14268:14268 -p 55678-55680:55678-55680 -p 6060:6060 -p 7276:7276 -p 8888:8888 \
    -p 9411:9411 -p 9943:9943 -v collector.yaml:/etc/collector.yaml:ro \
    --name otelcol quay.io/signalfx/splunk-otel-collector:0.1.0

In the case of Docker, a volume mount may be required to load custom configuration as shown above.

If the custom configuration includes a memory_limiter processor then the ballast_size_mib parameter should be the same as the SPLUNK_BALLAST_SIZE_MIB environment variable. See splunk_config.yaml as an example.

Monitoring

The default configuration automatically scrapes the Collector's own metrics and sends the data using the signalfx exporter. A built-in dashboard provides information about the health and status of Collector instances.

Troubleshooting

See the Collector troubleshooting documentation.

Directories

Path Synopsis
baseline module
cmd
otelcol command
Program otelcol is the OpenTelemetry Collector that collects stats and traces and exports to a configured backend.
Program otelcol is the OpenTelemetry Collector that collects stats and traces and exports to a configured backend.
examples
internal
tools module
pkg
splunkconf module
splunkta module
tests module
parity module

Jump to

Keyboard shortcuts

? : This menu
/ : Search site
f or F : Jump to
y or Y : Canonical URL