eni-vlan

IaaS sub-ENI CNI plugin for the Spiderpool cloud network provider.
eni-vlan creates VLAN sub-interfaces inside Pod network namespaces for cloud IaaS sub-ENI scenarios: the IP address, VLAN ID and MAC address are all allocated by the cloud platform and delivered through spiderpool-agent at Pod creation time. Before handing the interface to the Pod, eni-vlan performs a final connectivity validation of the cloud-assigned IP/VLAN/MAC triple, so misconfigured or not-yet-effective cloud bindings fail the Pod fast instead of producing a silently broken network.
eni-vlan does not support static VLAN configuration. If you need a plain VLAN sub-interface with a vlanId from the CNI config, use the community vlan CNI plugin — that is exactly its job. eni-vlan exists only for the dynamic IaaS sub-ENI scenario where VLAN/MAC/IP come from the cloud via spiderpool-agent.
| Feature |
Community vlan CNI |
eni-vlan |
| VLAN ID source |
Static CNI config |
spiderpool-agent (cloud-allocated) |
| MAC address |
Not managed |
Set to the real sub-ENI MAC from spiderpool-agent |
| IP assignment |
Any IPAM plugin |
Spiderpool IPAM |
| Connectivity validation |
None |
Pre-flight ARP probe of the IP/VLAN/MAC triple |
How It Works
flowchart TD
A["CNI ADD"] --> B["Parse K8S_POD_NAME / K8S_POD_NAMESPACE<br/>from CNI_ARGS"]
B --> C["IPAM (spiderpool):<br/>allocate IP + gateway"]
C --> D["GetWorkloadEndpoint via spiderpool-agent<br/>unix socket /var/run/spidernet/spiderpool.sock<br/>→ VLAN ID + sub-ENI MAC"]
D --> E["Create VLAN sub-interface on master,<br/>set real sub-ENI MAC,<br/>move into Pod netns, link up<br/>(no IP configured yet)"]
E --> F{"validateIaasNetConfig<br/>enabled?"}
F -- no --> I["Configure IP + routes<br/>from IPAM result"]
F -- yes --> G["ARP probe in Pod netns:<br/>sender IP = allocated IP<br/>sender MAC = interface real MAC<br/>target = gateway"]
G --> H{"Reply from<br/>gateway?"}
H -- "yes (config is live)" --> I
H -- "timeout × validationRetries" --> R["FAIL CLOSED:<br/>roll back IPAM (DEL)<br/>delete interface<br/>fail CNI ADD"]
I --> J["Return CNI result"]
style R fill:#8b1a1a,color:#fff
style J fill:#1a6b2f,color:#fff
Connectivity Validation
This is neither a classic "gateway reachability check" nor RFC 5227 IP-conflict detection. It is a final pre-flight validation of the cloud-assigned IP/VLAN/MAC triple: it verifies that an interface built with this exact configuration can actually talk to the outside world before the Pod starts.
Why it lives here and only here:
- IaaS fabrics enforce strict anti-spoofing: only packets with source IP = bound IP, source MAC = real sub-ENI MAC, and the correct VLAN tag are forwarded. ARP probes sourced from
0.0.0.0, unbound IPs, forged MACs or wrong VLANs are silently dropped.
- Consequently RFC 5227-style probing (
0.0.0.0 sender) is physically impossible, and the fabric's IP-MAC binding already rules out IP conflicts — no conflict detection is needed.
- At the IPAM plugin stage no interface exists yet (nothing to probe from); at the coordinator stage the IP is already configured, so the kernel passively answers ARP and pollutes fabric neighbor tables (see spiderpool #4582/#4588).
- The only safe window is inside eni-vlan: after the VLAN sub-interface exists with its real MAC and is up, but before any IP is configured.
The probe: an ARP request with sender IP = allocated IP, sender MAC = interface real MAC (kernel-filled, AF_PACKET SOCK_DGRAM), target = gateway IP, executed inside the Pod netns.
- Gateway replies → the whole cloud configuration is live, proceed.
- No reply after
validationRetries attempts → wrong VLAN / MAC not effective / IP-MAC binding not pushed. The CNI ADD fails closed: IPAM allocation is rolled back and the interface deleted.
IPv4 (ARP) only for now; IPv6 (NS/NA) is a TODO. If the IPAM result contains no IPv4 gateway, the check is skipped.
Configuration
Fields
| Field |
Type |
Required |
Default |
Description |
master |
string |
Yes |
— |
Host network interface (the ENI) to attach the VLAN sub-interface to |
mtu |
int |
No |
master MTU |
MTU for the VLAN sub-interface |
linkInContainer |
bool |
No |
false |
Whether the master link is in the container namespace |
validateIaasNetConfig |
bool |
No |
false |
Enable the pre-flight validation of the cloud-assigned IP/VLAN/MAC triple |
validationRetries |
int |
No |
3 |
ARP probe attempts before failing |
validationTimeoutMs |
int |
No |
500 |
Per-probe reply timeout in ms (real IaaS gateway ARP RTT measured at ~48ms) |
ipam |
object |
Yes |
— |
IPAM plugin config (spiderpool) |
The legacy vlanId and vlanMode fields are rejected with an error. These fields (and the CNI conf as a whole) are intended to be rendered and delivered by SpiderMultusConfig in the future.
Example
{
"cniVersion": "1.0.0",
"name": "eni-network",
"type": "eni-vlan",
"master": "eth0",
"validateIaasNetConfig": true,
"validationRetries": 3,
"validationTimeoutMs": 500,
"ipam": {
"type": "spiderpool"
}
}
spiderpool-agent must be running and its Unix socket must be accessible at /var/run/spidernet/spiderpool.sock.
Requirements
- Linux kernel with 802.1Q VLAN support
- Go 1.25+
- spiderpool deployed in the cluster
Building
# Clone the repository
git clone https://github.com/spidernet-io/eni-vlan.git
cd eni-vlan
# Download dependencies
make deps
# Build the binary for the current platform (outputs to ./bin/eni-vlan-<os>-<arch>)
make build
# Cross-compile
GOOS=linux GOARCH=amd64 go build -o bin/eni-vlan-linux-amd64 ./cmd/eni-vlan
GOOS=linux GOARCH=arm64 go build -o bin/eni-vlan-linux-arm64 ./cmd/eni-vlan
The compiled binary is the CNI plugin. Copy it to the CNI bin directory on each node (typically /opt/cni/bin/eni-vlan).
Project Structure
eni-vlan/
├── cmd/eni-vlan/ # Plugin entry point (main.go)
├── pkg/
│ ├── config/ # NetConf definition and validation
│ ├── networking/ # ARP-based connectivity validation
│ └── vlan/
│ ├── interface.go # VLAN create / delete / MAC update
│ └── service.go # CNI ADD flow (IPAM → agent → VLAN → validate → IP)
├── docs/
│ └── design.md # Detailed design specification
├── Makefile
└── go.mod
Documentation
See docs/design.md for the full design specification, including detailed flow diagrams, the GetWorkloadEndpoint API reference, the connectivity validation design, error handling table, and implementation notes.
License