econut

Safe shutdown for a Linux machine powered through an EcoFlow Delta 3 Ultra Plus or other EcoFlow UPS NUT/HID Supported Backup Battery.

When mains power fails and the EcoFlow's battery runs down to a level you choose, econut-guard shuts your machine down cleanly, before the battery runs out and cuts power hard. If mains comes back first, nothing happens.

By default: on battery and below 55% for 120 seconds → systemctl poweroff. Both numbers are yours to change.

$ econut status
● econut-guard: running, ARMED (will power the machine off)

  UPS        ecoflow@127.0.0.1:3493
  Power      on mains (OL CHRG)
  Battery    ████████████████████ 99%
  Shutdown   when on battery and below 55% for 120s
  Condition  not met (on mains)

First iteration, not a release. Mains-loss detection has been verified on one unit; a full battery-to-shutdown run has not. Once the guard is running it will power your machine off when the condition is met. Use --dry-run (below) if you want to watch first.

How it works

The EcoFlow's USB-A port speaks USB HID Power Device. NUT reads it, and econut-guard polls NUT every 5 seconds. The EcoFlow reports battery percentage and mains status (OL on mains, OB on battery) over USB. It does not report watts, load or temperature over USB. *Note if you're struggling to connect with the USB port on the Ecoflow marked 'HID' and using a USB-C to USB-C cable, change to USB-C - A or use an A adapter to force data / block self negotiation.

Requirements

  • Linux with systemd, and root access.
  • The EcoFlow's USB-A port connected to the machine you want to protect (a USB-C to USB-C cable did not work on the unit we tested).
  • NUT: sudo apt install nut-server (Debian/Ubuntu).
  • Go 1.22 or newer, to build.

Install

No clone needed. Two commands:

go install github.com/x7even/econut/cmd/...@latest
sudo ~/go/bin/econut install --enable-service

(~/go/bin is where go install puts the binaries; use $(go env GOBIN) or $(go env GOPATH)/bin if you have changed that. The full path matters because sudo often does not have it on PATH.)

To pick your own shutdown level at install time, add --shutdown-below 40.

The deployment files are built into the econut binary. econut install sets up the udev rule, the NUT configuration, the econut-guard service and copies both commands to /usr/local/bin. It is safe to re-run: files that already match are left alone and changed ones are backed up. sudo ~/go/bin/econut install --dry-run shows what it would do, and --uninstall removes it.

Prefer a checkout? git clone https://github.com/x7even/econut.git && cd econut && go build -o bin/ ./cmd/... && sudo deploy/install.sh --enable-service does the same thing.

Update

The same two commands, in the same order:

go install github.com/x7even/econut/cmd/...@latest
sudo ~/go/bin/econut install

Both are needed. go install only refreshes ~/go/bin; it does not touch /usr/local/bin, which is where the service runs from, and it does not restart anything. The second command is what updates the machine: it backs up the binaries it replaces, restarts a running econut-guard so the new one is actually live, and keeps your /etc/econut/econut.conf, so the shutdown level you chose survives the update. Add --enable-service if the guard was never enabled.

Then confirm the update took effect:

econut version    # which build this command is, and which build is running
econut check      # exit 0 means protected right now

econut version answers the update question directly, because it reports two builds rather than one:

econut        v0.3.2
econut-guard  v0.3.2 (running)

If the two differ, the daemon protecting the machine is not the build you just installed, and it says so and names the command that fixes it. econut-guard running, but does not report its version means the running guard predates v0.3.2, which is itself the answer: it is an older build than this one. A guard that has stopped is reported as not running rather than by the version in its last snapshot.

For a build from before v0.3.2, which cannot report itself, ask the toolchain instead:

go version -m /usr/local/bin/econut-guard | grep -w mod  # the build the service runs
systemctl show econut-guard -p ExecMainStartTimestamp    # it should post-date the update

A release build names the module and its tag, as in mod github.com/x7even/econut v0.3.0. A pseudo-version ending in +dirty, or a bare mod econut, is an uninstalled local build from before the rename, which means the copy into /usr/local/bin never ran. Swap the path for "$(command -v econut)" to ask the same of the CLI.

On-disk and running are separate questions, which is why the timestamp is there: it is the daemon that protects the machine, and it only picks up a new binary when it restarts.

Check it works

econut status                    # is the guard running, and what is the battery at?
journalctl -u econut-guard -f    # watch it live

Unplug the EcoFlow from mains for a few seconds and plug it back in. The journal shows what the unit reports, for example:

UPS values changed  ups.status="OL -> OB DISCHRG"
UPS values changed  ups.status="OB DISCHRG -> OL DISCHRG"
UPS values changed  ups.status="OL DISCHRG -> OL CHRG"

Both tiers of protection should check out too. Tier 1 is econut-guard, shutting down at the level you chose; tier 2 is NUT's own upsmon, shutting down if the UPS itself reports low battery (see deploy/README.md):

econut check                     # tier 1: protected right now? exit 0 if so
systemctl is-active nut-monitor  # tier 2: expect active, not failed
upsc -c ecoflow@localhost        # tier 2: must list a client
udevadm info -n /dev/ttyACM0 | grep ID_MM   # expect ID_MM_DEVICE_IGNORE=1

upsc -c is the one that matters: it lists who is logged in to upsd, and upsmon appearing there is the only proof its login succeeded. Given a password upsd rejects, upsmon stays running and retries for ever, so systemctl showing it active does not mean it is watching the battery. Expect one address, usually 127.0.0.1; upsc also prints Init SSL without certificate database on stderr, which is normal and is not a client. No address listed means there is no tier 2 - re-run the installer.

When it cannot see the UPS

A guard that is running is not necessarily protecting the machine. If the USB link or the NUT driver dies, every reading becomes unusable and a low battery would go unnoticed, so econut status says so plainly:

● econut-guard: running, NOT PROTECTED (no usable UPS reading for 84h0m0s; a low battery would not be noticed)

  UPS        <ups>
  Power      no reading for 84h0m0s (nut: <ups> ups.status: DRIVER-NOT-CONNECTED)
  Battery    unknown
  Shutdown   when on battery and below 55% for 120s
  Condition  UNKNOWN - nothing is watching the battery

The guard also logs a warning on the first failed read and escalates to an error once there has been no usable reading for --stale-after (default 300 s), repeating once per interval until a reading comes back. Blindness is measured from the last usable reading, not from the first failed poll. A run of failures that a reading bridges before any single poll crossed --stale-after is still reported when the reading returns, because a gap longer than --debounce is longer than the debounce can bridge: an outage inside it would not have powered the machine off.

Two more faults read as "running fine" if nobody checks for them, so they are part of the verdict as well:

  • The poweroff did not work. The guard asked the machine to shut down and the command failed. It retries on the next poll, and until one succeeds the status says NOT PROTECTED (it asked the machine to power off and that failed: ...) with a last poweroff attempt FAILED row. Telemetry can look perfect in this state.
  • ups.status cannot be interpreted. econut decides on the OB token alone, so a status carrying neither OB nor OL - a best-fit subdriver that signals discharge some other way, or reports nothing at all - says nothing about the power source. Reading the missing OB as mains would be silent and wrong, and acting on it would power the machine off on healthy mains, so it is reported instead: Power unknown ("DISCHRG").

econut status exits with the verdict, so a script can act on it:

code meaning
0 protected: running, live, last reading usable. The only zero exit.
1 not running: no status file, unreadable, not fresh, or dated in the future.
2 usage error.
3 running but unprotected through a fault: no usable reading, a ups.status that says neither OB nor OL, a poweroff attempt that failed, or an unrecognised mode.
4 running and reading the UPS, but in dry-run: unprotected by configuration.

For an unattended job, econut check is the one-line preflight:

econut check || exit 1            # refuse to start unless the machine is protected
econut check --max-age 10s        # also require a snapshot newer than 10 s
econut check --allow-dry-run      # accept a dry-run guard that can see the UPS
econut check --quiet              # exit code only

It reports the same verdict as econut status, from the same snapshot, and exits with the same code - with the two differences it exists for: --allow-dry-run turns exit 4 into exit 0, and --max-age can turn any other verdict into exit 1. A --max-age longer than the guard's own freshness window (three poll intervals) changes nothing, since it can only ever make the answer stricter.

Change the settings

sudo econut set --shutdown-below 40                       # shut down below 40% battery
sudo econut set --debounce 90s                            # ...after 90 s continuously below it
sudo econut set --shutdown-below 40 --debounce 90s        # or both

This saves to /etc/econut/econut.conf and restarts the guard. econut status shows the values in effect.

Try it without shutting down

Add --dry-run to the ExecStart= line in /etc/systemd/system/econut-guard.service, then sudo systemctl daemon-reload && sudo systemctl restart econut-guard. The guard logs WOULD shut down instead of acting, and econut status says dry-run. Remove the flag to arm it again.

Troubleshooting

  • sudo: .../econut: command not found: go install has not run, so ~/go/bin/econut does not exist yet - installing is two commands and that is the first one. If you have changed GOBIN, use $(go env GOBIN)/econut, or $(go env GOPATH)/bin/econut, instead.
  • An old version still running after go install: go install writes to ~/go/bin and nothing else. The service runs /usr/local/bin/econut-guard, which the install step copies into place before restarting it, so sudo ~/go/bin/econut install is what makes a new build live. econut version shows both builds at once and is the quickest way to see the gap; for a guard older than v0.3.2, go version -m /usr/local/bin/econut-guard | grep -w mod says which build is on disk, and systemctl show econut-guard -p ExecMainStartTimestamp whether the daemon has restarted onto it.
  • nut-monitor is failed, or upsc -c <ups> lists no client: tier 2 is down, so a low battery reported by the UPS itself would not shut the machine down. Re-run the installer (sudo ~/go/bin/econut install): it writes upsmon.conf with the password from upsd.users and then verifies the login. Tier 1 is unaffected, and econut check still speaks for it.
  • econut status says NOT RUNNING: systemctl status econut-guard and journalctl -u econut-guard -n 50.
  • econut status says NOT PROTECTED: the headline names which fault it is. Most often the guard is alive but cannot read the UPS; journalctl -u econut-guard -n 50 has the driver's own error, and upsc <ups> shows whether NUT can read it at all. Until this clears, nothing will shut the machine down.
  • NOT PROTECTED with last poweroff attempt FAILED: the UPS is fine and the shutdown command is not. The journal line shutdown action failed has the error; the guard runs systemctl poweroff, so check that it is running as root and that the command works when run by hand.
  • NOT PROTECTED with Power unknown: the read worked but ups.status says neither OB nor OL. upsc <ups> ups.status shows what the driver reports; a unit that signals discharge only through some other variable cannot be used by econut as it stands.
  • No reading from the UPS: upsc <ups> should list values; if it does not, check systemctl status nut-server nut-driver@ecoflow and that the cable is in the USB-A port.
  • NUT may bind a generic best-fit HID subdriver whose name does not match the hardware, so ups.status and battery.charge behaviour must be verified per unit with upsc <ups> rather than assumed. econut's decision reads only the OB token and battery.charge, never LB or battery.charge.low.
  • Colours off: set NO_COLOR=1, or pipe the output.

More detail is in deploy/README.md; design notes are in docs/.

Go standard library only. go test ./... runs the suite, and no test can power anything off.

MIT licensed.

Documentation

Overview

Package econut carries the deployment files (udev rule, NUT config, systemd unit, install script) inside the binaries, so `econut install` needs no repository checkout.

Index

Constants

This section is empty.

Variables

View Source
var Deploy embed.FS

Functions

This section is empty.

Types

This section is empty.

Directories

Path Synopsis
cmd
econut command
Command econut reports what econut-guard is doing: is it running, what the battery level is, and how close it is to shutting the machine down.
Command econut reports what econut-guard is doing: is it running, what the battery level is, and how close it is to shutting the machine down.
econut-guard command
Command econut-guard shuts the machine down when the UPS is on battery and the charge is low.
Command econut-guard shuts the machine down when the UPS is on battery and the charge is low.
internal
actuator
Package actuator performs the shutdown (Poweroff), or only logs it (LogOnly, for --dry-run).
Package actuator performs the shutdown (Poweroff), or only logs it (LogOnly, for --dry-run).
guard
Package guard wires a UPS source, the policy and an actuator into a poll loop.
Package guard wires a UPS source, the policy and an actuator into a poll loop.
nut
Package nut is a minimal client for the NUT upsd text protocol.
Package nut is a minimal client for the NUT upsd text protocol.
policy
Package policy decides when the rig should shut down.
Package policy decides when the rig should shut down.
status
Package status is the snapshot econut-guard publishes for the econut command.
Package status is the snapshot econut-guard publishes for the econut command.
version
Package version reports which build of econut is running.
Package version reports which build of econut is running.

Jump to

Keyboard shortcuts

? : This menu
/ : Search site
f or F : Jump to
y or Y : Canonical URL